HP claims PUE of 1.18 for its new modular data center design

 
Vendor says its ‘ultra-modular’ design cuts capital cost in half
(7/27/2010)


Each 'butterfly' consists of four 500-600 sq m centrally connected data center modules

HP says its new “ultra-modular” approach to data center design will enable 50-percent capital-cost savings associated with design and construction, in addition to dramatic reductions energy cost and deployment time. All of that also comes with a PUE of 1.18.

The company’s new “butterfly” design, unveiled Tuesday, consists of four prefabricated data center modules connected to a central administrative section. With 800kW per module, each butterfly delivers a total of 3.2MW of critical load.

“Clients, such as financial service providers, government entities and cloud and colocation hosts, will find the scalable and modular nature of HP Flexible DC a compelling option,” Kfir Godrich, CTO of HP’s Technology Services, said. “We are already talking to several people from government and the financial space about setting these up. With our four (flexible data centers) we think we are able to cater for most of the world.”

The patent-pending solution, called HP Flexible Data Center, or Flexible DC, is available now, with pricing varying according to location and implementation.


With four modules, a Flexible DC offers a total of 3.2MW of critical load

HP Critical Facilities Services, which delivers the Flexible DC, offers three electrical topology options: N Single utility source, N+1 UPS and 2N UPS. There is a variety of UPS options, including rotary, flywheel, offline, double conversion and delta conversion systems. According to HP, the offline UPS is the most efficient system, offering about 98 percent efficiency.

The system received power at medium voltage and transforms it directly to a server voltage of 415V/240V, reducing PDU transformer losses and the amount of electrical equipment required. There are no PDU’s within the sever room.

Power and water savings are also achieved by using air-cooled mechanical systems. The cooling design includes air-to-air heat exchangers with direct expansion refrigeration system. It employs indirect evaporation air-to-air heat exchangers with Dx assist and direct evaporation and heat transfer wheel with Dx assist.

Server rooms are arranged in a hot-aisle-contained configuration, with no raised floors.

According to HP, at $0.08 per kW, a 3.2MW Flexible DC will require about $2.6m in annual electricity cost.

Related news: i/o Data Centers reveals more details about new modular data center
Related feature: The new future of data centers
Related news: Colt launches its own modular data center design

Keywords: HP, ultra-modular data center, HP Flexible Data Center, butterfly design, PUE

Comment Box
 
You must sign in to post
 
Username 
Password 
No Blogger account? Sign up here.
CAPTCHA Validation
Retype the code from the picture
CAPTCHA Code Image
Speak the code Change the code
 
Articles:
  • The Next Phase of Data Centre Cooling
  • US academic institutions and the accelerated growth of cloud
  • Titan of the information age settles into a small rural town
  • Turning shortcomings in today's data center into new opportunities for investors
  • SGI tries adiabatic cooling to make a data center container greener
  • HP's award winning data center gets its own video
  • The new future of data centers
  • CONSTRUCTION: HSBC Cancels Plans for Second Data Center in Yorkshire
  • Data Center Design: One Size Does Not Fit All
  • COLOCATION: European Data Center Market Awaits Recovery, Reports CBRE
News:
  • WikiLeaks moves servers to underground data center in nuclear bunker
  • Six finalists emerge in fight for eBay data center contract
  • Purdue University offers details on HP’s POD to be used for supercomputing
  • Equinix spends $9m on Tokyo footprint
  • Green Data Systems opens modular ‘box in a box’ demo data center
  • India’s Tata Communications opens Singapore exchange
  • Belgacom helps customers monitor the cloud
  • Microsoft to build modular data center in Virginia
  • DRT completes two acquisitions
  • Saudi Arabia data center receives Tier III certification
Download Library:
  • Data centres: The backbone of the UK economy
  • Deploying High Density Zones in Low Density Data Centers
  • TIA-942 Data Center Standards
  • Server Room Solutions: How small to midsize IT departments can make their budgets appear larger than they are
  • Assessing Availability Options for Financial Services Companies
  • Power protection designs for maximum availability
  • A Review of Data Centre Tier Classifications
  • Rethinking Static Datacenters
  • Fresh Air Cooling in Data Centres: Overview of approach showing potential savings in operational costs
  • Critical and Hypercritical Facilities™: Security Considerations
DatacenterDynamics delivers knowledge and networking opportunities to professionals that design, build and operate data centers through a combination of conferences, magazines, websites and research products.
Keywords: computer rooms, server farms, datacomm facilities, telecom sites, data centres, colocation, carrier hotels, data center strategy,

© DatacenterDynamics 2010